GFA TS959 SELF DIAGNOSTIC DIGITAL CONTROL PANEL
Mains supply:
1N~230 V, PE; 3N~400 V, PE
3~230 V, PE; 3~400 V, PE
Operating frequency:
50 Hz / 60 Hz
Dimensions W x H x D:
with mains switch:
155 x 386 x 90 mm
155 x 386 x 117 mm
Hold-to-run control for:
Digital limit switch DES
Mechanical limit switch NES
IDs20095902 00002
GE29590G
TS 959 – Hold-to-run control panel for DES / NES limit switches
Housing
Dimensions WxHxD [mm]: 155x386x90(1182))
IP65 rated when hard wired or IP54 if CEE plug used
Protection against contact provided by covers for
live parts
Connection cable that plugs into the ELEKTROMATEN
unit, insertable from below or above
Design
Integrated OPEN-STOP-CLOSE control device
Safety reversing contactor (with 2 independent
shutdown options)
Settings via selector switch with digital display
Pluggable connection technology
Connection cable running to ELEKTROMATEN
available in various lengths
Independent, programmable relay contact, e.g.
usable for green traffic-lights or ramp enabling
Slack-rope and pass-door plug-in connection
points
Accessories
Mains switch/isolator
Emergency STOP switch
Key switch
For description and details on further accessories,
see 8.039
Functions
Automatic detection of DES or NES limit switches
Change of rotating direction from control panel
push buttons
Adjustment of limit positions (only DES) and all
functions from the operator level
Selectable operating mode:
• CLOSE/OPEN in hold-to-run mode
• CLOSE in hold-to-run mode/OPEN in self-hold mode
• Hold to run FULLY CLOSE FUNCTION/self-hold OPEN
Keep the CLOSE button pressed until the door is
completely CLOSED. If the CLOSE button is
released early, the door will reverse automatically
to its OPEN position.
Status and information display (including display of
6 most-recent faults); extended evaluation by using
optionally available GfA-Stick (see 8.039)
Cycle counter (non-resettable)
Maintenance-cycle counter:
• Setting range: 1,000-99,000 cycles
• Display indication or switch to hold-to-run operation
once the maintenance-cycle limit is reached
Detects door /drive blockage (only DES); in this
event the control deactivates the drive unit
Dynamic run time monitoring (only NES):
• With every door movement, the time taken to
run between the end positions is measured
and compared with the most-recently set
reference duration
• If the run duration is increased (pre-settable
deviation), the control panel is deactivated
Settable force monitoring in OPEN direction
(only DES):
• For counterbalanced doors, sudden changes to the
counter-balancing are detected
• Self-learning feature and consequently no activation
of force monitoring function due to,
e.g., a change in spring tension
Technical data
For GfA ELEKTROMATEN1) drives with DES or NES
Supply voltage:
1N~230 V, PE / 3~230 V, PE / 3N~400 V, PE / 3~400 V, PE
Operating frequency: 50 Hz / 60 Hz
Mains supply ratings for external devices: 230 V AC (1.6A)
Permissible temperature range: -10 °C...+50 °C